Publications
Please find below selected publications from EURAMET's European Metrology Research Programmes (EMRP and EMPIR) and the Metrology Partnership that are related to Clean Energy:
Annihilation of structural defects in chalcogenide absorber films for high-efficiency solar cells
Energy & Environmental Science 9 (2016) , 1818-1827
- Type:
- Article
- Project title:
- ENG53: ThinErgy: Traceable characterisation of thin-film materials for energy applications
- Name of Call / Funding Programme:
- EMRP A169: Call 2013 Energy II
- DOI
- 10.1039/c6ee00402d
Series arrays of NbSi barrier Josephson junctions for AC voltage standards
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) - Conference Digest n / a (2016) , 7540562 (2 pp.)
- Type:
- Proceedings
- Project title:
- SIB59: Q-WAVE: A quantum standard for sampled electrical measurements
- Name of Call / Funding Programme:
- EMRP A169: Call 2012 SI Broader scope (II)
- DOI
- 10.1109/CPEM.2016.7540562
Multi-mode absorption spectroscopy using a quantum cascade laser for simultaneous detection of NO and H2O
Applied Physics B 122 (2016) , 226
- Type:
- Article
- Project title:
- IND63: MetAMC: Metrology for airborne molecular contamination in manufacturing environments
- Name of Call / Funding Programme:
- EMRP A169: Call 2012 Metrology for Industry (II)
- DOI
- 10.1007/s00340-016-6499-4
ICL-based CO dTDLAS Sensor for Atmospheric Applications
Imaging and Applied Optics 2016 (2016)
- Type:
- Proceedings
- Project title:
- ENV52: HIGHGAS: Metrology for high-impact greenhouse gases
- Name of Call / Funding Programme:
- EMRP A169: Call 2013 Environment II
- DOI
- 10.1364/LACSEA.2016.LM3G.4
Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu
Applied Radiation and Isotopes 112 (2016) , 156-164
- Type:
- Article
- Project title:
- HLT11: MetroMRT: Metrology for molecular radiotherapy
- Name of Call / Funding Programme:
- EMRP A169: Call 2011 Metrology for Health
- DOI
- 10.1016/j.apradiso.2016.03.007
The Propagation Constant of Coaxial Offset Shorts with Rough Surfaces
CPEM 2014 Digest 2014 (2016) , 14-15
- Type:
- Proceedings
- Project title:
- SIB62: HFCircuits: Metrology for new electrical measurement quantities in high-frequency circuits
- Name of Call / Funding Programme:
- EMRP A169: Call 2012 SI Broader scope (II)
- DOI
- 10.1109/CPEM.2014.6898235
Nitrous oxide line positions in the 0002-0000 band at 2.26 µm as test case for high-resolution FTIR-spectrometer stability
Imaging and Applied Optics 2016 (2016) , JT3A.14
- Type:
- Article
- Project title:
- ENV06: EUMETRISPEC: Spectral Reference Data for Atmospheric Monitoring
- Name of Call / Funding Programme:
- EMRP A169: Call 2010 Environment
- DOI
- 10.1364/3D.2016.JT3A.14
Comparison of methods for measurement of equivalent source match
Proceedings of the 45th European Microwave Conference 2015 (2016) , 730-733
- Type:
- Proceedings
- Project title:
- SIB62: HFCircuits: Metrology for new electrical measurement quantities in high-frequency circuits
- Name of Call / Funding Programme:
- EMRP A169: Call 2012 SI Broader scope (II)
- DOI
- 10.1109/EuMC.2015.7345867
Extended S-parameters for imperfect test ports
Metrologia 52 (2016) , 121-129
- Type:
- Article
- Project title:
- SIB62: HFCircuits: Metrology for new electrical measurement quantities in high-frequency circuits
- Name of Call / Funding Programme:
- EMRP A169: Call 2012 SI Broader scope (II)
- DOI
- 10.1088/0026-1394/52/1/121
Generation of Whole-Body Scintigraphic Images with New GATE Output Capacities
IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), Seoul, 2013 (2016) , pp. 1-3.
- Type:
- Article
- Project title:
- HLT11: MetroMRT: Metrology for molecular radiotherapy
- Name of Call / Funding Programme:
- EMRP A169: Call 2011 Metrology for Health
- DOI
- 10.1109/NSSMIC.2013.6829150