The list shows all projects coordinated within the Technical Committee for Thermometry.

Projects TC-T

Subject Reg. No. Starting TITLE Coordinating Institute Status Collaboration Type KCDB
T 1167 2010-03-01 Comparison of the realisations of the ITS-90 over the range of 83.8058 K to 692.677 K MIRS/UL-FE/LMK concluded Comparison EURAMET.T-K3.4
T 412 1997-05-01 EUROMET T. K5 Extension: Intercomparison of local realizations of the ITS-90 above Silver point VSL completed Comparison EUROMET.T-K5
T 391 1996-11-15 Intercomparison of the freezing point of Indium JV completed Comparison EUROMET.T-S2
T 712 2004-01-01 Complementary comparison of Indium fixed point cells LNE-LCM/CNAM completed Comparison EUROMET.T-S2
T 621 2001-03-01 Key comparison(s) in humidity (dew-point temperature) MIKES completed Comparison EUROMET.T-K6
T 717 2004-01-01 Comparison in dew-point temperature (high range) PTB in progress Comparison EURAMET.T-K8
T 658 2003-07-01 The examination of base parameters for ITS-90 scale realization in radiation thermometry NPL completed Research EUROMET.T-S1
T 1403 2016-06-15 Tri-lateral comparison in humidity (dew-point temperature high range) 30 °C to 95 °C concluded Comparison EURAMET.T-K8.1
T 1422 2017-06-15 Bilateral comparison of ITS-90 SPRT calibration from the Hg TP to the Zn FP JV completed Comparison EURAMET.T-K9.1
T 1268 2013-10-01 Comparison of the calibration of thermocouples in fixed points and/or by comparison from 419,527 ºC (freezing point of zinc) up to 1492 ºC (Pd-C eutectic fixed point) CEM completed Comparison EURAMET.T-S3
T 1264 2013-02-28 Bilateral comparison of SPRT calibration at the ITS-90 fixed points of Ar, Hg, Ga, In, Zn and Al VSL completed Comparison EURAMET.T-K3.5
T 899 2006-06-01 Key comparison of water triple point cells (regional extension of CCT-K7) VSL completed Comparison EUROMET.T-K7
T 1401 2016-03-22 Star-shape comparisons of high temperature thermal conductivity measurement standards for insulation from 150 °C up to 650 °C NPL concluded Comparison EURAMET.T-S6
T 1402 2016-03-22 Round-Robin comparisons of high temperature thermal conductivity measurement standards for insulation from 150 °C to 650 °C NPL concluded Comparison EURAMET.T-S6
T 1524 2021-09-01 Supplementary comparison on thermal diffusivity measurements of high conductive materials by the laser flash method LNE-LCM/CNAM in progress Comparison EURAMET.T-S8
T 1147 2010-03-01 Key comparison EURAMET.T-K1: Realisations of the ITS-90, 2.4 K to 24.5561 K, using rhodium-iron resistance thermometers PTB completed Comparison EURAMET.T-K1
T 1392 2016-03-01 Comparison of the calibration of noble metal thermocouples up to 1100 ºC CEM completed Comparison EURAMET.T-S5
T 1357 2015-04-01 Inter-laboratory comparison of triple point of water (TPW) cells UME in progress Comparison EURAMET.T-K7.4
T 1098 2009-02-01 Comparison of the realisations of the ITS-90 over the range of 83.8058 K to 692.677 K UME concluded Comparison EURAMET.T-K3.2
T 1211 2011-10-01 Bilateral comparison of triple point of water cells VSL completed Comparison EURAMET.T-K7.3
T 552 2000-04-01 Comparison of the realisation of the ITS-90 over range 83.805 K to 692.677 K LNE-LCM/CNAM completed Comparison EUROMET.T-K3
T 1095 2008-03-01 Bilateral comparison of the realizations of the ITS-90- at the fixed points of Hg, H2, Ga, In, Sn and Zn BIM completed Comparison EURAMET.T-K3.1
T 1082 2008-08-01 Key comparison of water triple point cells (regional extension of CCT-K7) SMU completed Comparison EURAMET.T-K7.1
T 1163 2010-09-21 Comparison of Water Triple Point Cells VSL completed Comparison EURAMET.T-K7.2
T 1318 2014-12-01 EURAMET.T-K9 Regional key comparison: ITS-90 SPRT Calibration from the Ar TP to the Zn FP LNE-LCM/CNAM in progress Comparison EURAMET.T-K9
T 1457 2018-09-01 Comparison of measurement parameters required in radiance temperature scale realization from 156°C to 1100 °C INRIM in progress Comparison EURAMET.T-S7
T 820 2004-12-01 Comparison of the realizations of the ITS-90 at the freezing points of Al(660,323 °C) and Ag (961,78 °C) PTB completed Comparison EUROMET.T-K4
T 1015 2008-04-01 Trilateral comparison in fixed points of Zn, SN, In, Ga and Hg CMI completed Comparison
T 1022 2007-11-01 Traceability of dew/frost point temperature INRIM completed Traceabillity
T 1032 2008-04-01 High-range dew-point temperature realization using two-pressure generators INTA completed Research
T 1033 2008-11-01 Comparison of psychrometer calibrations - Pre-study FORCE completed Comparison
T 1034 2008-03-25 Determination of the water vapor pressure curve, between -100 °C and 100 °C, with a very high accuracy LNE-CETIAT completed Research
T 1035 2008-09-01 Adiabatic calorimeter in the 54K-273K temperature range LNE-LCM/CNAM completed Research
T 1036 2007-06-01 Extrapolation scheme for long stem thermometers range calibration down to 77K LNE-LCM/CNAM completed Research
T 1037 2007-06-01 Study of Argon triple point devices behaviour LNE-LCM/CNAM completed Research
T 43 1988-10-31 Triple points of carbon dioxide and deuterium NPL completed Research
T 119 1989-01-01 Gas and vapour-pressure thermometry between 1 and 25K INRIM completed Comparison
T 151 1994-01-01 Provision of traceability for absolute humidity NPL completed Traceabillity
T 181 1988-10-01 Thermal conductivity measurements of high temperature alloys NPL completed Comparison
T 217 1990-07-01 Exchange of information on calibration procedures LNE-CETIAT completed Research
T 237 1991-02-01 Radiometric measurement of the freezing points of silver and gold NPL completed Comparison
T 240 1990-04-01 Sources of uncertainty of ITS-90 fixed points between -200 C/+400 C. LNE-LCM/CNAM completed Research
T 249 1994-03-14 Training courses on temperature standards. NPL completed Research
T 253 1991-10-21 Comparison of temperature scales DTI completed Comparison
T 260 1992-09-01 Determination of non-uniqueness of the ITS-90 in the range between the aluminium and silver freezing points INRIM completed Research
T 278 1993-04-01 Intercomparison of water triple-point cell LNE-LCM/CNAM completed Comparison
T 279 1992-12-01 Multi-compartment cells for triple points in the cryogenic range LNE-LCM/CNAM completed Research
T 280 1992-12-01 Intercomparison of Mercury point cells LNE-LCM/CNAM completed Research
T 290 1993-03-08 Intercomparison of humidity generators with dew-point hygrometer MIKES completed Comparison
T 309 1994-03-01 ReproducIbility of the ITS-90 between 13,8 K and 303 K NPL completed Comparison