The list shows all projects coordinated within the Technical Committee for Thermometry.

Projects TC-T

Subject Reg. No. Starting TITLE Coordinating Institute Status Collaboration Type KCDB
T 770 2004-04-01 Determination of an accurate Ttp vs x(isotopic) relationship for neon INRIM completed Research
T 1336 2014-09-08 Consultation on IR Metrology at NSAI NLM, Ireland NSAI NML completed Consultation
T 1610 2024-01-01 Consultation on humidity standards and provision of traceability to LACOMET INRIM in progress Consultation
T 712 2004-01-01 Complementary comparison of Indium fixed point cells LNE-LCM/CNAM completed Comparison EUROMET.T-S2
T 1524 2021-09-01 Comparison on thermal diffusivity measurements of high conductive materials by the laser flash method LNE-LCM/CNAM in progress Comparison
T 1163 2010-09-21 Comparison of Water Triple Point Cells VSL completed Comparison EURAMET.T-K7.2
T 635 2001-12-01 Comparison of the Reference Surface Temperature Apparatus at NMIs by comparison of Transfer Surface Temperature Standards PTB completed Comparison
T 820 2004-12-01 Comparison of the realizations of the ITS-90 at the freezing points of Al(660,323 °C) and Ag (961,78 °C) PTB completed Comparison EUROMET.T-K4
T 1352 2015-10-01 Comparison of the realisations of the relative humidity in the range from 10% to 95% at temperatures from -40 °C to 20 °C INTA in progress Comparison
T 1189 2010-05-03 Comparison of the realisations of the relative humidity in the range from 10% to 95% at temperatures from -10 °C to 70 °C MIRS/UL-FE/LMK completed Comparison
T 1098 2009-02-01 Comparison of the realisations of the ITS-90 over the range of 83.8058 K to 692.677 K UME concluded Comparison EURAMET.T-K3.2
T 1167 2010-03-01 Comparison of the realisations of the ITS-90 over the range of 83.8058 K to 692.677 K MIRS/UL-FE/LMK concluded Comparison EURAMET.T-K3.4
T 1236 2011-05-19 Comparison of the realisations of the ITS-90 over the range of 234.3156 K to 692.677 K MIRS/UL-FE/LMK completed Comparison
T 1382 2015-09-01 Comparison of the realisations of the dewpoint temperature in the range from -40 °C to 20 °C MIRS/UL-FE/LMK completed Comparison
T 552 2000-04-01 Comparison of the realisation of the ITS-90 over range 83.805 K to 692.677 K LNE-LCM/CNAM completed Comparison EUROMET.T-K3
T 1328 2014-07-14 Comparison of the dew-point temperature in range from -50 °C to +20 °C between GUM and CMI GUM completed Comparison
T 1268 2013-10-01 Comparison of the calibration of thermocouples in fixed points and/or by comparison from 419,527 ºC (freezing point of zinc) up to 1492 ºC (Pd-C eutectic fixed point) CEM completed Comparison EURAMET.T-S3
T 1251 2012-06-01 Comparison of the calibration of standard platinum resistance thermometers in the range -80 °C to 300 °C by comparison MIRS/UL-FE/LMK completed Comparison
T 1392 2016-03-01 Comparison of the calibration of noble metal thermocouples up to 1100 ºC CEM completed Comparison EURAMET.T-S5
T 1249 2012-03-19 Comparison of the calibration of liquid in glass thermometers in the range -30 °C to 150 °C MIRS/UL-FE/LMK completed Comparison
T 253 1991-10-21 Comparison of temperature scales DTI completed Comparison
T 1149 2010-05-01 Comparison of surface temperature calibrations BFKH in progress Comparison
T 778 2004-12-01 Comparison of realisations of aluminum and silver freezing-point temperatures PTB completed Comparison
T 1033 2008-11-01 Comparison of psychrometer calibrations - Pre-study FORCE completed Comparison
T 1457 2018-09-01 Comparison of measurement parameters required in radiance temperature scale realization from 156 °C to 1100 °C INRIM in progress Comparison EURAMET.T-S7
T 625 2000-03-01 Comparison of fixed point cells (TP of Hg, MP of Ga, FP of Sn, FP of Zn, FP of Al, FP of Ag) and comparison of the W at the argon point MIRS/UL-FE/LMK completed Comparison
T 808 2004-09-01 Comparison of calibration facilities MIKES completed Consultation
T 927 2007-03-01 Comparison of blackbodies for calibration of infra-red ear thermometers MIRS/UL-FE/LMK completed Comparison
T 1061 2008-09-01 Comparison of Air Temperature Calibrations MIKES completed Comparison
T 717 2004-01-01 Comparison in dew-point temperature (high range) PTB in progress Comparison EURAMET.T-K8
T 869 2005-10-12 Co-operation in humidity between NMISA and MIKES MIKES completed Traceabillity
T 1294 2013-11-01 Circulation of Pond Eng. Ar Triple Point System K-38 VSL in progress Research
T 737 2002-11-01 Calibration facility for the low dew-point temperature range MIKES completed Consultation
T 1338 2014-09-15 Bilateral international comparison of the standard platinum resistance thermometer (SPRT) in the temperature range from -40 °C to 230 °C UME completed Comparison
T 655 2002-01-01 Bilateral intercomparison of the calibration of type S thermocouples in the fixed points of Zn, Al, Ag and Au VSL completed Comparison
T 1429 2017-11-27 Bilateral comparison on triple point cells of mercury SMU completed Comparison
T 895 2006-05-15 Bilateral comparison of water triple point cells INRIM completed Comparison
T 1211 2011-10-01 Bilateral comparison of triple point of water cells VSL completed Comparison EURAMET.T-K7.3
T 1127 2009-05-06 Bilateral comparison of triple point of mercury and melting point of gallium MIRS/UL-FE/LMK completed Comparison
T 1095 2008-03-01 Bilateral comparison of the realizations of the ITS-90- at the fixed points of Hg, H2, Ga, In, Sn and Zn BIM completed Comparison EURAMET.T-K3.1
T 1058 2008-04-03 Bilateral comparison of the realisations of the ITS-90 at the mercury point DTI completed Comparison
T 1178 2010-09-01 Bilateral comparison of the realisations of the ITS-90 at the freezing points of Al (660,323 °C) and Ag (961,78 °C) SMD completed Comparison
T 1317 2014-04-01 Bilateral comparison of the realisations of the ITS-90 at the freezing points of Al (660,323 °C) and Ag (961,78 °C) LNE-LCM/CNAM concluded Comparison
T 1137 2009-11-15 Bilateral comparison of the dew point temperature between TUBITAK UME and NIS UME completed Comparison
T 1264 2013-02-28 Bilateral comparison of SPRT calibration at the ITS-90 fixed points of Ar, Hg, Ga, In, Zn and Al VSL completed Comparison EURAMET.T-K3.5
T 1094 2008-03-01 Bilateral comparison of Relative Humidity Calibration BIM completed Comparison
T 1335 2014-09-01 Bilateral comparison of radiation thermometers MIRS/UL-FE/LMK completed Comparison
T 1366 2015-03-16 Bilateral comparison of radiation thermometers MIRS/UL-FE/LMK completed Comparison
T 1394 2016-04-01 Bilateral comparison of radiation thermometers MIRS/UL-FE/LMK completed Comparison
T 916 2006-09-01 Bilateral comparison of mercury triple point cells INTiBS completed Comparison
167 result(s)