A new Calibration and Measurement Capability (CMC) was published in the BIPM key comparison data-base in October 2016. The new CMC from IPQ (Portugal) belongs to the field of volume measurements and refers to the calibration of micropipettes using the photometric method (PCS - Pipette Calibration System from Artel). It is so far, the smallest volume capability of any National Metrology Institute (NMI), 10-7 L.

There are two methods used for calibration of micropipettes: The gravimetric method (ISO 8655-6:2002) and the photometric method (ISO 8655-7:2005). The gravimetric method is commonly used by NMIs and Accredited Laboratories to calibrate volume instruments, including micropipettes. This method consists of weighing a delivered volume of the micropipette into a beaker placed on a balance.

The alternative photometric method uses a high-resolution photometer with colorimetric analysis to determine the volume delivered by a micropipette. The basic principle behind photometric measurement is the conservation of mass and the Lambert-Beer Law. In this method, an unknown volume of red dye is delivered into a vial containing a known volume and concentration of blue dye. After mixing, the change in absorbance of the resulting volume can be calculated as a ratio.

In micropipettes the uncertainty component that has a major contribution to the final uncertainty depends on the volume determined. In the photometric method for small volumes the repeatability is the largest uncertainty component but for large volumes, bigger than 100 µL, the instrument will be the most significant source of uncertainty. This is the opposite of the results obtained by the gravimetric method, where the balance is the largest source of uncertainty, and that can get to 30 % of the measured volume for 0,1 µL. In the photometric method the uncertainty for the described volume will be 2 % and therefore the best method to be used for smaller volumes is the photometric method.

Select your area of interest
EMPIR project develops new radon sources to improve exposure measurements and greenhouse gas tracing
2024-02-29

The sources will improve atmospheric transport models which can be used to track both radon and greenhouse gases more

Project publishes video entitled ‘Small field dosimetry for MR guided radiotherapy’
2024-02-27

Supporting innovations in combined imaging and radiation cancer treatment by standardising dose measurements more

Long completed EURAMET projects still providing benefit to Europe
2024-02-23

Between 2009 and 2013 EURAMET funded 119 research projects – many of which continue to benefit European citizens, businesses, and the environment more

Supporting improved electromagnetic compatibility measurements in harsh environments and real time
2024-02-21

Metrology Partnership project is developing the standardised measurements required to protect modern electronics from radio-interference more

EMPIR project helps deliver new tool in the fight against cancer
2024-02-13

FLASH radiotherapy is a new form of cancer treatment promising to minimise damage caused to healthy tissue but requiring metrology for its safe use more

Page 3 of 225.